SpecGuard

Construction submittal review
Back to recent runs
COMPLETED SAMPLE

Run e7829d9b

This run was audited before submittal numbers were assigned, so it is identified by its run ID.

Created 2026-08-22 16:43:23.850656+00:00

Claims made
1
Findings persisted
1
Rejected
0
Retried
0
Open the RFI draft PDF Export this run as JSON

The JSON export carries findings, rejections, integrity records, document hashes, severity, token usage, and timestamps. It carries no filesystem path and no passphrase.

Audit model usage

Exact Gemini token counts from ADK metadata. SpecGuard does not estimate missing counts.

Prompt tokens
31570
Output tokens
333
Total tokens
33286

Tool calls the model initiated

Every tool call the model itself initiated, in the order it made them, as the ADK event stream reported them. A call the runtime made to build the message is not a model decision and is not listed here.

This run recorded no model-initiated tool call. In full_text mode both documents are sent up front, so the model can return its claims without reading more; when it does call a read-only tool such as verify_quote to check its own quote, that call is listed here.

Findings QUOTES VERIFIED

Both quotes were found at their cited pages. This is not a judgment that the discrepancy is real.

StatusClaimSpecification quote in contextSubmitted quote in contextSeverity
QUOTES VERIFIEDThe specification requires conductor terminations to be rated for a minimum of 90 deg C, but the submittal specifies a field conductor termination rating of 158 deg F (equivalent to 70 deg C).Specification page 5Conductor terminations shall be rated 90 deg C minimum.
Specification page 5, as the gate read it

…y learning workshop · project no. alw-2026-e01 division 26 · electrical section 26 05 19 · low-voltage electrical power conductors and cables part 2 · products 2.1 terminations a. conductor terminations shall be rated 90 deg c minimum. b. use listed terminals that accept the conductor size installed at each location. c. provide plated contact surfaces where the listed terminal requires them. d. do not install co…

Submitted page 2Field conductor termination rating: 158 deg F.
Submitted page 2, as the gate read it

…and documentation data submittal data sheet 3. field connection data & termination ratings field connection parameter submittal requirement & field provision field connection data field conductor termination rating: 158 deg f. accepted conductor material copper conductors within the marked lug range. installation access front removable barriers support routine field landing work. torque information ship…

UNCLASSIFIEDfallback

Reason: severity endpoint not deployed outside demo windows

Severity is an advisory Gemma annotation on already-verified findings. It is not part of verification.

Each shaded block is the cited page as the gate read it: extracted with PyMuPDF, then normalized by the gate's own normalizer, and bounded to a window either side of the quote. The highlighted run is the exact text the gate matched. Run the same check yourself.

Rejections REJECTED

Claims the gate refused, with the exact reason code it returned.

No claims were rejected for this run.

Integrity records QUARANTINED

Hidden text found in the document text layer. No model read this text.

No text-layer integrity record exists for this run.

Chain-of-custody metadata

The hex run ID and the SHA-256 of every source and generated file, in full. These identify the byte streams this run read and wrote. They are chain-of-custody metadata only. They do not prove accuracy, and no part of the verification gate reads them.

Run ID
e7829d9bc7264334b4421da802160c06
RoleObjectSHA-256
specificatione7829d9bc7264334b4421da802160c06/specification.pdf88988353d0332a32c3dcdf47225e150814a92277beb920cdfc919de9d3dfe568
submitted_documente7829d9bc7264334b4421da802160c06/submitted-document.pdfccf31f40e3bc28c3e589d0a00740531fc43f16b48504c6cdd9716b2e47b2faab
RFIe7829d9bc7264334b4421da802160c06/rfi.pdf4fd1e3a4df2199e0162ab985a5c99e6307fd4ccbe0b2c236168302515c5479c2