e7829d9bThis run was audited before submittal numbers were assigned, so it is identified by its run ID.
Created 2026-08-22 16:43:23.850656+00:00
The JSON export carries findings, rejections, integrity records, document hashes, severity, token usage, and timestamps. It carries no filesystem path and no passphrase.
Exact Gemini token counts from ADK metadata. SpecGuard does not estimate missing counts.
Every tool call the model itself initiated, in the order it made them, as the ADK event stream reported them. A call the runtime made to build the message is not a model decision and is not listed here.
This run recorded no model-initiated tool call. In full_text mode both documents are sent up front, so the model can return its claims without reading more; when it does call a read-only tool such as verify_quote to check its own quote, that call is listed here.
Both quotes were found at their cited pages. This is not a judgment that the discrepancy is real.
| Status | Claim | Specification quote in context | Submitted quote in context | Severity |
|---|---|---|---|---|
| QUOTES VERIFIED | The specification requires conductor terminations to be rated for a minimum of 90 deg C, but the submittal specifies a field conductor termination rating of 158 deg F (equivalent to 70 deg C). | Specification page 5Conductor terminations shall be rated 90 deg C minimum.
Specification page 5, as the gate read it
…y learning workshop · project no. alw-2026-e01 division 26 · electrical section 26 05 19 · low-voltage electrical power conductors and cables part 2 · products 2.1 terminations a. conductor terminations shall be rated 90 deg c minimum. b. use listed terminals that accept the conductor size installed at each location. c. provide plated contact surfaces where the listed terminal requires them. d. do not install co… | Submitted page 2Field conductor termination rating: 158 deg F.
Submitted page 2, as the gate read it
…and documentation data submittal data sheet 3. field connection data & termination ratings field connection parameter submittal requirement & field provision field connection data field conductor termination rating: 158 deg f. accepted conductor material copper conductors within the marked lug range. installation access front removable barriers support routine field landing work. torque information ship… | UNCLASSIFIEDfallback Reason: severity endpoint not deployed outside demo windows Severity is an advisory Gemma annotation on already-verified findings. It is not part of verification. |
Each shaded block is the cited page as the gate read it: extracted with PyMuPDF, then normalized by the gate's own normalizer, and bounded to a window either side of the quote. The highlighted run is the exact text the gate matched. Run the same check yourself.
Claims the gate refused, with the exact reason code it returned.
No claims were rejected for this run.
Hidden text found in the document text layer. No model read this text.
No text-layer integrity record exists for this run.
The hex run ID and the SHA-256 of every source and generated file, in full. These identify the byte streams this run read and wrote. They are chain-of-custody metadata only. They do not prove accuracy, and no part of the verification gate reads them.
e7829d9bc7264334b4421da802160c06| Role | Object | SHA-256 |
|---|---|---|
| specification | e7829d9bc7264334b4421da802160c06/specification.pdf | 88988353d0332a32c3dcdf47225e150814a92277beb920cdfc919de9d3dfe568 |
| submitted_document | e7829d9bc7264334b4421da802160c06/submitted-document.pdf | ccf31f40e3bc28c3e589d0a00740531fc43f16b48504c6cdd9716b2e47b2faab |
| RFI | e7829d9bc7264334b4421da802160c06/rfi.pdf | 4fd1e3a4df2199e0162ab985a5c99e6307fd4ccbe0b2c236168302515c5479c2 |